1.1 This practice covers the process of development of data quality objectives (DQOs) for the acquisition of environmental data. Optimization of sampling and analysis design is a part of the DQO process. This practice describes the DQO process in detail. The various strategies for design optimization are too numerous to include in this practice. Many other documents outline alternatives for optimizing sampling and analysis design. Therefore, only an overview of design optimization is included. Some design aspects are included in the practice’s examples for illustration purposes.
1.2 DQO development is the first of three parts of data generation activities. The other two aspects are (1) implementation of the sampling and analysis strategies, see Guide D6311 and (2) data quality assessment, see Guide D6233.
1.3 This guide should be used in concert with Practices D5283, D6250, and Guide D6044. Practice D5283 outlines the quality assurance (QA) processes specified during planning and used during implementation. Guide D6044 outlines a process by which a representative sample may be obtained from a population, identifies sources that can affect representativeness and describes the attributes of a representative sample. Practice D6250 describes how a decision point can be calculated.
1.4 Environmental data related to waste management activities include, but are not limited to, the results from the sampling and analyses of air, soil, water, biota, process or general waste samples, or any combinations thereof.
1.5 The DQO process is a planning process and should be completed prior to sampling and analysis activities.
1.6 This practice presents extensive requirements of management, designed to ensure high-quality environmental data. The words “must“ and “shall“ (requirements), “should“ (recommendation), and “may“ (optional), have been selected carefully to reflect the importance placed on many of the statements in this practice. The extent to which all requirements will be met remains a matter of technical judgment.
1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7.1 Exception – The values given in parentheses are for information only.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.