Click here to purchase

1.1 This test method is intended as a screening test to determine if the solids in a paint contain more than 0.06% lead. The test described can differentiate between 0.05 and 0.06%. Paints giving a result greater than 0.05% should be analyzed quantitatively for lead using Test Method D3335. This test method provides a more definitive and reliable screening test than Test Method D3618.

1.2 There is no reason to believe that higher levels of lead could not be determined by this test method provided that appropriate dilutions and adjustments in specimen size and reagent quantities are made.

1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Product Details

Published:
05/10/1998
Number of Pages:
3
File Size:
1 file , 57 KB