1.1 These test methods cover testing of concrete pipe, manhole sections, and tile. The test methods described are used in production testing and acceptance testing to evaluate the properties provided for in the specifications.
1.2 The test methods appear in the following order:
Section | |
External Load Crushing Strength | 4 |
Flat Slab Top | 5 |
Core Strength | 6 |
Absorption | 7 |
Hydrostatic | 8 |
Permeability | 9 |
Manhole Step | 10 |
Cylinder Strength | 11 |
1.3 The test specimens shall not have been exposed to a temperature below 4°C for the 24 h immediately preceding the test.
1.4 If any test specimen fails because of mechanical reasons such as failure of testing equipment or improper specimen preparation, it shall be discarded and another specimen taken.
1.5 Specimens shall be selected in accordance with the specifications for the type of pipe or tile being tested.
1.6 These methods are the metric companion of Test Methods C 497.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Product Details
- Published:
- 10/01/2005
- Number of Pages:
- 14
- File Size:
- 1 file , 280 KB
- Redline File Size:
- 2 files , 540 KB