This paper provides an overview of the model developed for simulation of steady-state performance of a heat pump working with a nonazeotropic binary mixture. The modeled heat pump consists of a hermetic, reciprocating compressor, flat-finned tube heat exchangers, a constant flow area expansion device, an accumulator, a four-way valve, and connecting tubing.
The paper discusses basic concepts in formulation of models of major heat pump components and overall program iteration scheme . Verification of the model is presented in the cooling and heating operating modes for a heat pump charged with R13B1/Rl52a mixture.
Units: I-P
Citation: Symposium, ASHRAE Transactions, 1985, vol. 91, pt. 2B, Honolulu, HI
Product Details
- Published:
- 1985
- Number of Pages:
- 15
- File Size:
- 1 file , 1.1 MB
- Product Code(s):
- D-HI-85-27-3