The newly revised edition of NFPA 82, Standard on Incinerators and Waste and Linen Handling Systems and Equipment provides base-line requirements for the fire-safe installation, construction, maintenance, and use of compactors, containers, incinerators, waste storage rooms, and waste, linen, and laundry systems to reduce risks and minimize damages. (Softbound, 26 pp., 2019)

Product Details

Published:
01/01/2019
Number of Pages:
26

Click here to purchase
Reduce fire risks for incinerators and waste handling systems with the 2009 NFPA 82!

Rely on NFPA 82: Standard on Incinerators and Waste and Linen Handling Systems and Equipment for the fire-safe installation and use of waste storage rooms; containers; incinerators; compactors; and waste, linen, and laundry handling systems.

Among the changes in the 2009 edition of NFPA 82 that improve safety are:

  • The scope of the standard now includes requirements for maintenance.
  • New definitions of Gravity Chute intake door, pneumatic chute loading door, general access chute, and limited access chute
  • Chapter 8 has been retitled Waste and Recyclables Storage Rooms.
  • Requirements have also been revised in Chapter 8 to include the term recyclables due to the emphasis of recycling and LEED/green buildings.
  • A new Chapter 10 has been established on Maintenance of Incinerators and Waste and Linen Handling Systems and Equipment.

This important document is a must for facility owners and managers, waste and linen chute manufacturers and designers, insurers, and AHJs.

Product Details

Published:
2009
Number of Pages:
29

Click here to purchase
Reduce fire risks for incinerators and waste handling systems with the 2014 edition of NFPA 82.

Turn to NFPA 82: Standard on Incinerators and Waste and Linen Handling Systems and Equipment for the fire-safe installation and use of:

  • Waste storage rooms
  • Containers
  • Incinerators
  • Compactors
  • Waste, linen and laundry handling systems

The 2014 edition of this document uses the terms “fire resistance rating” and “fire protection rating” in alignment with their usage in other NFPA? documents. In addition, all uses of “loading,” “service opening” and “service loading” have been changed to “intake” to match real-world industry usage.

Other updates to NFPA 82 include:

  • A definition for a “chute discharge door” has been added to differentiate between the types of doors used in chute operations.
  • To reflect current practice, the use of a fire damper has been added in lieu of a fire door. (The fire damper provides the same level of protection, but features a much more effective seal at the opening and has fewer maintenance concerns.)
  • The fire protection rating for the openings in the chute enclosure are consistent with other changes included in this edition.
  • Requirements for external-fed waste compactors have been expanded by adding a definition to clarify how an external waste compactor differs from a waste compactor. Also, specific requirements have been added to Chapter 8 to address the main hazard of external waste compactors: the risk of fire and smoke spreading from the compactor back into the building.
  • Requirements for decommissioning a chute have been added to give users guidance on removing the chute door while maintaining the rating of the chute enclosure.