Click here to purchase

1.1 This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. It does not include grout, reinforcing, anchorage, or control joints since their use is essentially the same as conventional concrete masonry construction, unless specifically mentioned in this practice.

Note 1: Design and construction procedures for conventional concrete masonry construction are found in Building Code Requirements for Masonry Structures (TMS 402-16) and Specification for Masonry Structures (TMS 602-16).

Product Details

Published:
06/01/2023
Number of Pages:
3
File Size:
1 file , 250 KB
Redline File Size:
2 files , 310 KB
Note:
This product is unavailable in Russia, Ukraine, Belarus