1.1 This specification covers the requirements for monolithic flat heat-strengthened and fully tempered coated and uncoated glass produced on a horizontal tempering system used in general building construction and other applications.
1.2 This specification does not address bent glass, or heat-strengthened or fully tempered glass manufactured on a vertical tempering system.
1.3 The dimensional values stated in SI units are to be regarded as the standard. The units given in parentheses are for information only.
1.4 The following safety hazards caveat pertains only to the test method portion, Section 10, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Product Details
- Published:
- 03/15/2012
- Number of Pages:
- 7
- File Size:
- 1 file , 140 KB
- Redline File Size:
- 2 files , 280 KB