1.1 This specification covers nonreinforced concrete pipe to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1 and for use in drainage.

1.2 A complete SI companion to Specification C118 has been developed-C118M; therefore, no SI equivalents are presented in this specification.

Note 1 – This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation.

TABLE 1 Standard Dimensions, Working Pressure, and Test Requirements for Standard Concrete Irrigation PipeA

Internal Designated Diameter, in. Thickness
of Wall,
T, in.
Working
Pressure,B
ft
Minimum Internal Hydrostatic Test Pressure, psi Minimum
Three-Edge-Bearing
Load, lbf/linear ft
6 7/8 30 50 1300
8 1 30 50 1350
10 11/8 30 50 1400
12 1¼ 25 45 1500
14 1³/8 25 45 1600
15 1½ 25 45 1650
16 1½ 25 45 1700
18 1¾ 25 45 1800
20 2 25 40 1850
21 21/8 25 40 1900
24 2¼ 25 40 2000

A For hydrostatic test requirements, refer to 10.5.

B Higher working pressures are not prohibited up to a maximum of 40 ft for 6 through 8-in. diameters, 35 ft for 10 through 12-in. diameters, and 30 ft. for 14-in. through 24-in. diameters. In these cases, the strength of the pipe shall be increased to give a minimum of at least four times the design working pressure when tested as specified in 10.5.