1.1 This test method covers the determination of slow crack growth (SCG) parameters of advanced ceramics by using constant stress-rate flexural testing in which flexural strength is determined as a function of applied stress rate in a given environment at ambient temperature. The strength degradation exhibited with decreasing applied stress rate in a specified environment is the basis of this test method which enables the evaluation of slow crack growth parameters of a material.
Note 1
This test method is frequently referred to as “dynamic fatigue” testing (Refs
Note 2
In glass and ceramics technology, static tests of considerable duration are called “static fatigue” tests, a type of test designated as stress-rupture (See Definitions E 1823).
1.2 Values expressed in this test method are in accordance with the International System of Units (SI) and
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Product Details
- Published:
- 01/01/2006
- Number of Pages:
- 10
- File Size:
- 1 file , 160 KB
- Redline File Size:
- 2 files , 290 KB