Click here to purchase

1.1 This practice covers molding cylindrical test specimens from concrete when the standard procedures of rodding and internal vibration, as described in Practice C 31/C 31M and Practice C 1176, are not practicable. This practice is applicable to freshly-mixed concrete, prepared in the laboratory and the field.

1.2 Freshly-mixed concrete is molded in cylindrical molds using an electric vibrating hammer equipped with a shaft and circular plate.

1.3 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the inch-pound units are shown in brackets. The values stated in each system may not be exact equivalents, therefore, each system must be used independently of each other without combining in any way.

1.4 The text of this practice references notes and footnotes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this practice.

1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Product Details

Published:
05/01/2005
Number of Pages:
5
File Size:
1 file , 160 KB