1.1 This specification covers the evaluating of the performance of heavy duty shielded couplings to join hubless cast iron soil pipe and fittings.
1.2 Couplings covered by this standard shall have minimum dimensions as found in Table 1 and Fig. 1 of this standard.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 The committee with jurisdiction over this standard is aware of comparable standards published by other organizations, namely Cast Iron Soil Pipe Institute specification CISPI 310 and Factory Mutual Research standard FM 1680.
1.5 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
TABLE 1
Nominal Pipe Size | Coupling Width |
---|---|
1½ to 4 in. (38 to 100 mm) | 3 in. (76 mm) Minimum Width |
5 to 10 in. (127 to 254 mm) | 4 in. (100 mm) Minimum Width |
12 to 15 in. (305 to 381 mm) | 5½ in. (140 mm) Minimum Width |
FIG. 1 Typical Center Stop Detail
Product Details
- Published:
- 10/15/2009
- Number of Pages:
- 12
- File Size:
- 1 file , 440 KB
- Redline File Size:
- 2 files , 840 KB