1.1 This test method covers the determination of the thermal diffusivity of carbons and graphite to ±5 % at temperatures up to 500 °C. It requires only a small easily fabricated specimen. Thermal diffusivity values in the range from 0.04 cm²/s to 2.0 cm²/s are readily measurable by this test method; however, for the reason outlined in Section 5, for materials outside this range this test method may require modification.
Product Details
- Published:
- 10/01/2015
- Number of Pages:
- 4
- File Size:
- 1 file , 110 KB