1.1 This practice covers the use of thermal insulations formed by a number of thermal radiation shields positioned perpendicular to the direction of heat flow. These radiation shields consist of alternate layers of a low-emittance metal and an insulating layer combined such that metal-to-metal contact in the heat flow direction is avoided and direct heat conduction is minimized. These are commonly referred to as multilayer insulations (MLI) or super insulations (SI) by the industry.
1.2 The practice covers the use of these insulation constructions where the warm boundary temperatures are below approximately 450 K.
1.3 Insulations of this construction are used when apparent thermal conductivity less than 0.007 W/mK (0.049 Btuin./hft 2F) at 300k are required.
1.4 Insulations of this construction are used in a vacuum environment.
1.5 This practice covers the performance considerations, typical applications, manufacturing methods, material specification, and safety considerations in the use of these insulations in cryogenic service.
1.6 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.7 his standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.