Click here to purchase

1.1 This test method covers determination of the pullout strength of hardened concrete by measuring the force required to pull an embedded metal insert and the attached concrete fragment from a concrete test specimen or structure. The insert is either cast into fresh concrete or installed in hardened concrete. This test method does not provide statistical procedures to estimate other strength properties.

Product Details

Published:
05/01/2015
Number of Pages:
10
File Size:
1 file , 440 KB
Redline File Size:
2 files , 880 KB