1.1”This practice governs procedures and references ASTM specifications for underground installation of thermoplastic pressure piping, 63”’in. (1372”’mm) nominal size and smaller. It is beyond the scope of this practice to describe these procedures in detail since it is recognized that significant differences exist in their implementation depending on kind and type of pipe material, pipe size and wall thickness, soil conditions, and the specific end use.
1.1.1”This practice assumes that over the range of anticipated operating conditions, including maximum external loading and minimum internal pressure, the soil/pipe system will offer sufficient structural stability to resist possible excessive diametrical deformation, or even collapse. In cases, particularly with large diameter thinner-walled pipe, for which the validity of this assumption may be in question, the selection of pipe and recommended installation conditions shall be determined by a qualified engineer.
Product Details
- Published:
- 07/01/2021
- Number of Pages:
- 8
- File Size:
- 1 file , 150 KB
- Redline File Size:
- 2 files , 300 KB