1.1 These test methods cover the determination of soluble iodide and bromide ions, or both, in brackish water, seawater, and brines. Four test methods are given as follows:

1.1.1 Test Method A for both Iodide and Bromide IonsVolumetric, for concentrations from 0.2 to 2000 mg/L iodide and from 5 to 6500 mg/L bromide (Sections 7-15).

1.1.2 Test Method B for Iodide IonColorimetric, for concentrations from 0.2 to 2000 mg/L iodide (Sections 16-25).

1.1.3 Test Method C for Iodide IonSelective electrode, for concentrations from 1 to 2000 mg/L iodide (Sections 26-34).

1.1.4 Test Method D for Bromide IonColorimetric, for concentrations from 40 to 6500 mg/L bromide (Sections 35-44).

1.2 Test Method A is intended for use on all brackish waters, seawaters, and brines that contain appreciable amounts of iodide or bromide ions or both. Test Methods B, C, and D, because of their rapidity and sensitivity, are recommended for the analysis of brackish waters, seawaters, and brines in the field and in the laboratory.

1.3 Samples containing from 0.2 to 2000 mg/L of iodide or 5 to 6500 mg/L of bromide may be analyzed by these methods.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 20.2 and 39.2.

7.1 This test method is applicable to brackish waters, seawaters, and brines, and is recommended for such waters containing appreciable amounts of iodide or bromide, or both. The test method can be used for concentrations as high as 2000 mg/L iodide and 6500 mg/L bromide.

16.1 This test method covers the colorimetric determination of iodide in brackish water, seawater, and brines where concentrations range from 0.2 to 2000 mg/L.

26.1 This test method is applicable to all brackish waters, seawaters, and brines containing from 1 to 2000 mg/L iodide.

35.1 This test method is applicable to all brackish waters, seawaters, and brines with bromide concentrations ranging from 40 to 6500 mg/L.

Product Details

Published:
05/15/2009
Number of Pages:
12
File Size:
1 file , 170 KB
Redline File Size:
2 files , 290 KB