1.1 This practice provides tables of volume correction factors which may be used to convert volumes of asphalt measured at different temperatures to a volume at a standard base temperature. These tables are applicable to all types of asphalts except emulsified asphalts.
1.2 This practice provides tables to convert asphalt volumes to 15C or 60F from volumes measured at any temperature from 25 to +275C or 0 to 500F.
1.3 The conversions from the two tables are not equivalent because the temperatures of 15C and 60F that they are based on are not equal.
Note 1
Correction factors in and are for use in place of correction factors provided in Guide D 1250, which do not address requirements for asphalt specifications.
Product Details
- Published:
- 06/01/2004
- Number of Pages:
- 10
- File Size:
- 1 file , 100 KB
- Redline File Size:
- 2 files , 300 KB