1.1 These test methods cover the methods and procedures for testing electrically insulating and semi-nonmetallic conducting rubber tapes designed for splicing, terminating, and sheath repair of electrical wire and cable.
1.2 The test methods appear in the following sections:
Section | |
Referenced Documents | 2 |
Conditioning | 5-6 |
Dielectric Strength | 33-40 |
Dimensions | 11-16 |
Dissipation Factor | 22-26 |
Elongation | 17-21 |
Heat Exposure | 46-49 |
Fusion | 7-10 |
Ozone Resistance | 41-45 |
Permittivity | 22-26 |
Sample Requirements | 4 |
Tensile Strength | 17-21 |
Volume Resistivity | 27-34 |
Ultraviolet and Weather Resistance | 50-54 |
1.3 The SI values are the standard. The inch-pound values given in parentheses are for information purposes only.
Note 1 – There is no IEC equivalent to these methods.
1.4 Unless otherwise stated, measurements are made on tapes from which the removable separator has been removed.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precaution statements see 43.1.
1.6 This is a fire-test response standard.
Product Details
- Published:
- 03/10/2002
- Number of Pages:
- 6
- File Size:
- 1 file , 48 KB
- Redline File Size:
- 2 files , 93 KB