Click here to purchase

1.1 This test method is to be used for determination of the acid extractable content of a sample of activated carbon. This test method presupposes the existence of substances other than carbon to be present with activated carbon but does not purport to address or identify those substances which may be present. This test method should be applicable to any form in which activated carbon may exist and requries the performance of Test Method D2866.

1.2 This test method requires the use of concentrated hydrochloric acid, which should be used in an appropriate and safe manner, with eye protection, skin protection and handling carried out in a properly operating fume hood. The proper use of a muffle furnace is addressed in Test Method D2866.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Product Details

Published:
02/10/1999
Number of Pages:
2
File Size:
1 file , 61 KB