1.1 This multi-test method covers the determination of the oxyhalides–chlorite, bromate, and chlorate, and bromide, in raw water, finished drinking water and bottled (non-carbonated) water by chemically and electrolytically suppressed ion chromatography. The ranges tested using this method for each analyte were as follows:
Range | Sections | |
---|---|---|
Test Method A: Chemically Suppressed Ion Chromatography |
8 to 18 | |
Chlorite | 20 to 500 µg/L | |
Bromate | 5 to 30 µg/L | |
Bromide | 20 to 200 µg/L | |
Chlorate | 20 to 500 µg/L | |
Test Method B: Electrolytically Suppressed Ion Chromatography |
19 to 29 | |
Chlorite | 20 to 1000 µg/L | |
Bromate | 1 to 30 µg/L | |
Bromide | 20 to 200 µg/L | |
Chlorate | 20 to 1000 µg/L |
1.1.1 The upper limits may be extended by appropriate sample dilution or by the use of a smaller injection volume. Other ions of interest, such as fluoride, chloride, nitrite, nitrate, phosphate, and sulfate may also be determined using this method. However, analysis of these ions is not the object of this test method.
1.2 It is the user’s responsibility to ensure the validity of these test methods for waters of untested matrices.
1.3 This test method is technically equivalent with Part B of U.S. EPA Method 300.1 , titled “The Determination of Inorganic Anions in Drinking Water by Ion Chromatography“.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Product Details
- Published:
- 08/15/2008
- Number of Pages:
- 21
- File Size:
- 1 file , 250 KB
- Redline File Size:
- 2 files , 520 KB