1.1 These multi-test methods cover the determination of the oxyhalides-chlorite, bromate, and chlorate, and bromide, in raw water, finished drinking water and bottled (non-carbonated) water by chemically and electrolytically suppressed ion chromatography. The ranges tested using these test methods for each analyte were as follows:
|
Range |
Sections |
Test Method A: |
|
8 to 20 |
Chlorite |
5 to 500 µg/L |
|
Bromate |
1 to 25 µg/L |
|
Bromide |
5 to 250 µg/L |
|
Chlorate |
5 to 500 µg/L |
|
|
|
|
Test Method B: |
|
21 to 31 |
Chlorite |
20 to 1000 µg/L |
|
Bromate |
1 to 30 µg/L |
|
Bromide |
20 to 200 µg/L |
|
Chlorate |
20 to 1000 µg/L |
|