Click here to purchase

1.1”This test method covers the determination of the thermal stability of unused organic heat transfer fluids. The procedure is applicable to fluids used for the transfer of heat at temperatures both above and below their boiling point (refers to normal boiling point throughout the text unless otherwise stated). It is applicable to fluids with maximum bulk operating temperature between 260””’C (500””’F) and 454””’C (850””’F). The procedure shall not be used to test a fluid above its critical temperature. In this test method, the volatile decomposition products are in continuous contact with the fluid during the test. This test method will not measure the thermal stability threshold (the temperature at which volatile oil fragments begin to form), but instead will indicate bulk fragmentation occurring for a specified temperature and testing period. Because potential decomposition and generation of high pressure gas may occur at temperatures above 260””’C (500””’F), do not use this test method for aqueous fluids or other fluids which generate high-pressure gas at these temperatures.

Product Details

Published:
12/01/2020
Number of Pages:
5
File Size:
1 file , 87 KB
Redline File Size:
2 files , 170 KB