Click here to purchase

1.1”These test methods cover laboratory compaction methods used to determine the relationship between molding water content and dry unit weight of soils (compaction curve) compacted in a 4 or 6-in. (101.6 or 152.4-mm) diameter mold with a 5.50-lbf (24.5-N) rammer dropped from a height of 12.0 in. (305 mm) producing a compactive effort of 12”’400 ft-lbf/ft³”'(600 kN-m/m³).

Note 1:The equipment and procedures are similar as those proposed by R. R. Proctor (Engineering News Record”’September 7, 1933) with this one major exception: his rammer blows were applied as ”’12 inch firm strokes”’ instead of free fall, producing variable compactive effort depending on the operator, but probably in the range 15”’000 to 25”’000 ft-lbf/ft³”'(700 to 1200 kN-m/m³). The standard effort test (see 3.1.4) is sometimes referred to as the Proctor Test.

Product Details

Published:
07/01/2021
Number of Pages:
13
File Size:
1 file , 330 KB