Click here to purchase

1.1 This test method covers the determination of selected elements in middle distillate fuels by inductively coupled plasma atomic emission spectrometry (ICP-AES). The specific elements are listed in Table 1. The concentration range of this test method is approximately 0.1 to 2.0 mg/kg. The test method may be used for concentrations outside of this range; however, the precision statements may not be applicable. Middle distillate fuels covered in this test method have all distillation fractions contained within the boiling range of 150 to 390°C. This includes, but is not limited to, diesel fuels and aviation turbine fuels.

Element

Wavelengths, nm

Aluminum

308.215, 396.153

Barium

455.403, 493.408

Calcium

393.366

Chromium

267.716, 283.563

Cobalt

228.615, 236.375, 238.892

Copper

324.752

Iron

259.939

Lithium

670.784

Lead

224.688, 283.306

Magnesium

279.553

Manganese

257.610

Molybdenum

204.597, 281.616

Nickel

221.648, 341.476

Phosphorus

214.914, 213.618

Palladium

340.458, 342.124

Platinum

214.423

Potassium

766.490

Sodium

588.995

Silicon

251.611

Silver

328.068

Strontium

407.771

Tin

283.999, 189.991

Titanium

334.940

Vanadium

310.230

Zinc

213.857