Click here to purchase

1.1 This test method covers the quantitative determination of water down to 20 ppm in plastics using a relative humidity sensor.

1.2 Values stated in SI units are to be regarded as standard.

1.3 Specimens tested in this test method can reach or exceed 250°C, use caution when handling them after testing has completed.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 1 – There is no known ISO equivalent to this standard.

Product Details

Published:
04/01/2010
Number of Pages:
4
File Size:
1 file , 80 KB
Redline File Size:
2 files , 150 KB