1.1 This test method covers the determination of the complex shear modulus of bituminous mixtures using torsion rectangular geometry on a dynamic shear rheometer (DSR). It is applicable to bituminous mixtures having complex shear modulus values greater than 1 × 104 Pa when tested over a range of temperatures from 10°C to 76°C at frequencies of 0.01 to 25 Hz and strains of 0.001 % to 0.1 %. The determination of complex shear modulus is typically determined at 20°C to 70°C at 0.01% strain at 10 discrete frequency values covering 0.01 to 10 Hz. From these data, temperature or frequency master curves can be generated as required. This test method is intended for determining the complex shear modulus of bituminous mixtures as required for specification testing or quality control of bituminous mixture production.
Product Details
- Published:
- 08/01/2014
- Number of Pages:
- 11
- File Size:
- 1 file , 440 KB