1.1 These test methods cover the atomic absorption determination of dissolved and total recoverable manganese in water and certain wastewaters. Three test methods are given as follows:
Test Method |
Concentration Range |
Sections |
A – Atomic Absorption, Direct |
0.1 to 5 mg/L |
7 to 15 |
B – Atomic Absorption, Chelation-Extraction |
10 to 500µg/L |
16 to 24 |
C – Atomic Absorption, Graphite Furnace |
5 to 50 µg/L |
25 to 33 |