1.1 This specification covers rigid, closed cell, polyurethane and polyisocyanurate thermal insulation for sandwich panels used in shelter construction for exposure to ambient temperatures of −25 to 160 °F (−32 to 71 °C). Painted surfaces of shelters in actual field use reach temperatures of 200 °F (93 °C). The materials in this specification must be capable of withstanding processing, (laminating) temperatures of 230 °F (110 °C).