1.1 These test methods cover the following procedures for determining the structural properties of segments of floor and roof constructions:

SectionTest SpecimensLoadingDeformation MeasurementsReportPrecision and BiasTesting FloorsTransverse LoadConcentrated LoadTesting RoofsTransverse LoadConcentrated Load

1.2 Metric units (SI) are to be considered as the primary standard units.

1.3 These test methods serve to evaluate the performance of floors and roofs panels subjected to (1) Uniform loading, and (2) Concentrated static loading, which represent conditions sustained in the actual performance of the element. The standard is not intended for the evaluation of individual structural framing and/or supporting members (floor joist, rafters and trusses).

1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of the standard.

1.5 This standard is not intended to cover concrete floor slabs.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.