1.1 This guide is intended to establish procedures and methodologies for conducting inspections of building facades including those that meet inspection criteria for compliance with Practice E2270. For the purposes outlined in this guide, unsafe conditions are hazards which could result from loss of facade materials.
1.2 Investigative techniques discussed may be intrusive, disruptive or destructive. It is the responsibility of the investigator to establish the limitations of use, to anticipate and advise of the destructive nature of some procedures, and to plan for patching and selective reconstruction as necessary.
1.3 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. Establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Awareness of safety and familiarity with safe procedures are particularly important for aboveground operations on the exterior of a building and destructive investigative procedures that typically are associated with the work described in this standard.
Product Details
- Published:
- 12/01/2011
- Number of Pages:
- 8
- File Size:
- 1 file , 97 KB