1.1”This test method describes the analysis of titanium and its alloys by spark atomic emission spectrometry (Spark-AES) and glow discharge atomic emission spectrometry (GD-AES). The titanium specimen to be analyzed may be in the form of a disk, casting, foil, sheet, plate, extrusion, or some other wrought form or shape. The elements and ranges covered in the scope by spark-AES of this test method are listed below.
Element |
Tested Mass Fraction Range (%) |
Aluminum |
0.008 to 7.0 |
Chromium |
0.006 to 0.1 |
Copper |
0.014 to 0.1 |
Iron |
0.043 to 0.3 |
Manganese |
0.005 to 0.1 |
Molybdenum |
0.014 to 0.1 |
Nickel |
0.006 to 0.1 |
Silicon |
0.018 to 0.1 |
Tin |
0.02 to 0.1 |
Vanadium |
0.015 to 5.0 |
Zirconium |
0.013 to 0.1 |
Product Details
- Published:
- 12/01/2021
- Number of Pages:
- 15
- File Size:
- 1 file , 130 KB
- Redline File Size:
- 2 files , 250 KB
- Note: