1.1”This practice covers the use of an eddy current array (ECA) or an eddy current sensor for nondestructive examination of carbon steel welds. It includes the detection and sizing of surface-breaking cracks in such joints, accommodating for nonmagnetic and nonconductive coating up to 5 mm thick between the sensor and the joint. The practice covers a variety of cracking defects, such as fatigue cracks and other types of planar discontinuities, at various locations in the weld (heat-affected zone, toe area, and weld cap, for example). It covers the length and depth sizing of such surface-breaking discontinuities. This practice can be used for flush-ground and not flush-ground welds. For specific ferrous alloys or specific welded parts, the user may need a more specific procedure.
Product Details
- Published:
- 11/01/2021
- Number of Pages:
- 6
- File Size:
- 1 file , 87 KB
- Redline File Size: