1.1 This practice covers the desirable and minimum information to be communicated between the originator and the user of data derived from constant-force amplitude axial, bending, or torsion fatigue tests of metallic materials tested in air and at room temperature.
Note 1 – Practice E466, although not directly referenced in the text, is considered important enough to be listed in this standard.
Product Details
- Published:
- 10/01/2011
- Number of Pages:
- 6
- File Size:
- 1 file , 130 KB
- Redline File Size:
- 2 files , 270 KB