1.1 This test method establishes a procedure for comparing the elemental composition of normal surfaces with any defects found on the surfaces of metal tubing, fittings, valves, or any metal component.
1.2 This test method applies to all steel surfaces of components such as tubing, connectors, regulators, and valves, regardless of size, style, or type.
1.3 Limitations:
1.3.1 This test method is intended for use by scanning electron microscope/energy dispersive x-ray spectrometer (SEM/EDX) operators with skill level typically achieved over a twelve-month period.
1.3.2 SEM used for this study should conform to those limitations outlined in Test Method
1.4 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 6.
Product Details
- Published:
- 01/01/2005
- Number of Pages:
- 4
- File Size:
- 1 file , 99 KB