1.1 This practice describes the procedures for the rehabilitation of sewer lines and conduits, 6 to 48 in. in diameter, by the insertion of a machine-made field-fabricated spiral wound liner pipe into an existing pipeline. After insertion, the spiral wound liner pipe is expanded until it presses against the interior surface of the existing pipeline, or, alternatively, the spiral wound liner pipe is inserted as a fixed diameter into the existing pipeline and is not expanded, and the annular space between the spiral wound liner pipe and the existing pipe is grouted. This rehabilitation process can be used in a variety of gravity applications such as sanitary sewers, storm sewers, culverts, and process piping.
1.2 The values in parentheses are provided for information purposes only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.3.1 Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces.
Product Details
- Published:
- 01/01/2001
- Number of Pages:
- 7
- File Size:
- 1 file , 92 KB