1.1 This test method measures the non-steady state heat transfer through flame resistant materials for clothing subjected to a continuous, combined convective and radiant heat exposure.
1.1.1 This test method is not applicable to materials that are not flame resistant.
Note 1–The determination of a material's flame resistance shall be made prior to testing and done according to the applicable performance or specification standard, or both, for the material's end-use.