1.1 These test methods cover two tests as follows:
1.1.1 Method A, Ferric Sulfate-Sulfuric Acid Test (Sections 3 – 10, inclusive)–This test method describes the procedure for conducting the boiling ferric sulfate-50 % sulfuric acid test which measures the susceptibility of certain nickel-rich, chromium-bearing alloys to intergranular corrosion (see Terminology G193), which may be encountered in certain service environments. The uniform corrosion rate obtained by this test method, which is a function of minor variations in alloy composition, may easily mask the intergranular corrosion components of the overall corrosion rate on alloys N10276, N06022, N06059, and N06455.
Product Details
- Published:
- 12/01/2022
- Number of Pages:
- 7
- File Size:
- 1 file , 230 KB
- Redline File Size:
- 2 files , 640 KB
- Note:
- This product is unavailable in Russia, Ukraine, Belarus