Examines the use of computer simulation to determine window frame U-factors. Makes s detailed comparison between computer-simulated values of window frame performance and detailed testing for seven different windows. Then uses the same computer simulation technique to determine representative frame U-factors covering the full range of window material types and operating styles. States these results will be used to expand Table 5 (previously Table 13) of chapter 27 of the 1993 ASHRAE Handbook – Fundamentals.
KEYWORDS: Models, calculating, computers, performance, windows, window frames, transmittance, comparing, testing.
Units: Dual
Citation: Symposium, ASHRAE Transactions 1993, Vol.99, pt.1