Click here to purchase

A field evaluation comparing the performance of low emittance (low-e) storm windows with both standard clear storm windows and no storm windows was performed in a cold climate. Six homes with single-pane windows were monitored over the period of one heating season. The homes were monitored with no storm windows and with new storm windows. The storm windows installed on four of the six homes included a hard coat, pyrolitic, low-e coating while the storm windows for the other two homes had traditional clear glass. Overall heating load reduction due to the storm windows was 13% with the clear glass and 21% with the low-e windows. Simple paybacks for the addition of the storm windows were 10 years for the clear glass and 4.5 years for the low-e storm windows.

Presented at Thermal Performance of Exterior Envelopes of Whole Buildings X – December 2007

Units: Dual

Citation: Thermal Performance of Exterior Envelopes of Whole Buildings X

Product Details

Published:
2008
Number of Pages:
8
File Size:
1 file , 2 MB
Product Code(s):
D-BldgsX22