1 Scope

1.1 ISA-TR84.00.02-2002 – Part 1 is informative and does not contain any mandatory clauses. ISATR84.00.02-2002 is intended to be used only with a thorough understanding of ANSI/ISA-84.01-1996(see Figure I.1). Prior to proceeding with use of ISA-TR84.00.02-2002 in a safety application, theHazards and Risk Analysis must have been completed and the following information provided

a) It is determined that a SIS is required.
b) Each safety instrumented function to be carried out by the SIS(s) is defined.
c) The SIL for each safety instrumented function is defined.

1.2 ISA-TR84.00.02-2002 – Part 1 provides

a) guidance in Safety Integrity Level analysis;
b) methods to implement Safety Instrumented Functions (SIF) to achieve a specified SIL;
c) discussion of failure rates and failure modes (Annex D) of SIS and their components;
d) discussion of diagnostic coverage, covert faults, common cause, systematic failures, redundancy ofSIF;
e) tool(s) for verification of SIL; and
f) discussion of the effect of functional test interval.

1.3 The objective of ISA-TR84.00.02-2002 – Part 1 is to introduce the reader to the performance basedapproach for evaluating the reliability of SIF and to present system reliability methodologies that can beused to evaluate the system performance parameters, namely, the probability that the SIF fails to respondto a demand and the probability that the SIF creates a nuisance trip. ISA-TR84.00.02-2002 – Part 1serves as an introduction for all other parts.

Product Details

Published:
06/17/2002
Number of Pages:
108