Keep stored emergency power supply systems (SEPSS) reliable and safe with the 2019 edition of NFPA 111.

NFPA 111: Standard on Stored Electrical Energy Emergency and Standby Power Systems is key anywhere an Uninterruptable Power Supply (UPS) is needed in the event of a disruption of the normal utility supply. This Standard covers performance requirements for stored electric energy systems providing an alternate source of electrical power in buildings and facilities during an interruption of the normal power source. It’s used in industries such as finance, IT, and certain areas of health care — anywhere continuous emergency power is legally required and/or a loss of power is unacceptable, even for a short duration.Improve life safety through reliable SEPSS.

Poor maintenance of battery systems is a common cause of failure in Stored Emergency Power Supply Systems (SEPSS). NFPA 111 includes installation, maintenance, operation, and testing requirements as they pertain to the SEPSS performance. Provisions address every area of the system including:

  • Power sources
  • Transfer equipment
  • Controls
  • Supervisory equipment
  • Accessory equipment needed to supply electrical power to selected circuits

To enhance usability, this edition has been revised to cover the interruption time without reference to specific SEPSS types.

The 2019 edition of NFPA 111 is essential for designers, engineers, contractors, installers, and facility managers of any building that requires a UPS according to NFPA 101?: Life Safety Code? or another code. In addition to improving occupant safety, compliance with NFPA 111 saves money by extending the life of the system through proper care (Softbound, 32 pp., 2019)

Product Details

Published:
01/13/2018
ISBN(s):
9781455919826
ANSI:
ANSI Approved
Number of Pages:
33

Click here to purchase
Design, install, and maintain stored emergency power supply systems for safety and reliability with the 2016 NFPA 111.

Where an Uninterruptable Power Supply (UPS) is needed in the event of a disruption of the normal utility supply, NFPA 111: Standard on Stored Electrical Energy Emergency and Standby Power Systems is key. This Standard covers performance requirements for stored electric energy systems providing an alternate source of electrical power in buildings and facilities during an interruption of the normal power source. It’s used in industries such as finance, IT, and certain areas of health care — anywhere continuous emergency power is legally required and/or a loss of power is unacceptable, even for a short duration.

Improve life safety through reliable SEPSS.

Poor maintenance of battery systems is a common cause of failure in Stored Emergency Power Supply Systems (SEPSS). In addition to improving occupant safety, compliance with NFPA 111 saves money by extending the life of the system through proper care. The Standard includes installation, maintenance, operation, and testing requirements as they pertain to the SEPSS performance. Provisions address every area of the system including:

  • Power sources
  • Transfer equipment
  • Controls
  • Supervisory equipment
  • Accessory equipment needed to supply electrical power to selected circuits

The 2016 edition of NFPA 111 has the latest coverage for designers, engineers, contractors, installers, and facility managers of any building that requires a UPS according to NFPA 101®: Life Safety Code® or another code. This edition includes revised baseline tests to obtain more accurate information, and revised load tests to correlate with international standards and facilitate the usability of the Standard throughout the world.

Product Details

Published:
06/15/2015
ISBN(s):
9781455911707
ANSI:
ANSI Approved
Number of Pages:
34

Click here to purchase
Get the latest on stored emergency power supply systems in the 2013 NFPA 111.

Readiness of emergency power is a key consideration in safeguarding building occupants in the event of a disruption of the normal utility supply. NFPA 111: Standard on Stored Electrical Energy Emergency and Standby Power Systems covers performance requirements for stored electric energy systems providing an alternate source of electrical power in buildings and facilities during an interruption of the normal power source.

Requirements in NFPA 111 address:

  • Power sources
  • Transfer equipment
  • Controls
  • Supervisory equipment
  • Accessory equipment needed to supply electrical power to selected circuits
  • Installation, maintenance, operation, and testing requirements as they pertain to the performance of the stored emergency power supply system (SEPSS).

Stay up-to-code and maximize safety with new options for stored power systems.

Changes in the 2013 edition include the addition of a rectifier plant — commonly used in the telecommunications industry — as a potential stored emergency power supply system, or as a suitable bridging system.

Product Details

Published:
06/18/2012
ISBN(s):
9781455904228
Number of Pages:
28