Click here to purchase

Codes and standards published by NFPA are displayed as read-only under license from NFPA solely for use within this system.  NFPA material may not be downloaded, printed, reproduced, or transferred.

Reduce hazards around marinas and boatyards by complying with NFPA 303 requirements.

Injuries from fire and electrical shock and environmental damage resulting from spilled hazardous materials are a significant concern in and around marinas and related facilities. NFPA 303, Fire Protection Standard for Marinas and Boatyards, helps protect people and property by offering strategies and provisions for establishing an acceptable level of safety.

Referenced in NFPA 1, Fire Code, this vital standard provides criteria for the construction and operation of marinas, boatyards, yacht clubs, boat condominiums, and docking facilities, including associated piers, docks, and floats. Content also covers support facilities and structures used in building, repairing, fueling, and storing vessels if at risk in the event of a fire.

From management and operational hazards to fire protection, electrical equipment and wiring, and berthing and storage, you get access to broad-based knowledge for helping to safeguard these structures and facilities.

The 2021 edition is essential for anyone involved with or responsible for safety in marinas and boatyards.

NFPA 303 has been updated to account for the overall lack of awareness amongst boat owners that dangerous ground-fault leakages can occur on their vessels. The latest edition further addresses electrical hazards with new requirements that apply retroactively to all marinas within two years of adoption of this edition.

The standard now states that vessels are to be tested for the presence of AC ground faults at the time of the initial connection to a marina electrical system. This rule applies to vessels that have not been constructed in accordance with the shore-power ground-fault requirements of Article 555 of NFPA 70®, National Electrical Code®. Vessels are not to be permitted to connect to the marina system if they display ground-fault leakage exceeding 30 mA.

Additional changes include:

  • Amended provision for receptacle configurations of less than 30 amperes and no more than 50 amperes to require these devices to be of a locking and grounding type that is listed and labeled
  • New language specifying the minimum width of fire department access roads
  • Revised fire protection requirements for in-out dry storage and rack storage
  • Added requirements that standpipe systems be designed and installed in accordance with NFPA 14 and portable fire extinguishers be provided in accordance with NFPA 10
  • Updated requirement for automatic fire-extinguishing systems for covered piers in excess of 5000 ft2
  • New requirement that operators of marinas and boatyards keep a record of employee training related to fire drills
  • Addition that guidance information be provided for signage at berths and slips to facilitate reporting of fires or other emergencies

Get up to speed with marina safety by purchasing NFPA 303, 2021 edition.

Fire personnel, construction professionals, facility owners and managers, insurance professionals, and AHJs rely on NFPA 303 for the knowledge they need to help minimize risks and work toward eliminating incidents completely. Make sure you have the latest information by ordering your copy today.

Product Details

Published:
04/04/2020
ANSI:
ANSI Approved
Number of Pages:
30

Click here to purchase
Reduce fire and electrical risks at marinas and related facilities with strategies in the 2016 NFPA 303.

Every year, marina fires and electric shock incidents cause numerous deaths and injuries, in addition to incurring millions of dollars in property loss along with environmental damage from hazardous materials spills. Most of these incidents, including the large number of fires and casualties directly related to electrical faults, could be prevented through compliance with NFPA 303: Fire Protection Standard for Marinas and Boatyards.

This important Standard establishes a minimum acceptable level of safety to life and property from fire and electrical hazards at marinas and related facilities, including boatyards, yacht clubs, boat condominiums, and docking facilities. Now referenced in NFPA 1: Fire Code, the requirements in NFPA 303 help minimize risks with the goal of eliminating them altogether.

Significant changes in the 2016 NFPA 303 target problem areas identified by recent events and reported data from the National Fire Incident Reporting System:

  • New reference to NFPA 70®: National Electrical Code® (NEC®) for the installation of ground fault protection in marinas and boatyards, along with new regular testing, to address Electric Shock Drowning (ESD) deaths
  • New provisions for maintaining firefighting equipment and electrical equipment, and protecting portable fire extinguishers, to help identify and mitigate the negative effects of harsh environmental exposures and conditions
  • Revised requirements for inspection, testing, and maintenance of firefighting equipment incorporate references to all applicable NFPA® standards
  • New requirement for facility pre-fire plans to be submitted to the AHJ annually for greater oversight
  • New requirement for pre-fire plans to include a more detailed list of firefighting equipment within the facility, along with employee responsibilities during emergency situations
  • New requirements for isolation valves in standpipe systems and clarification of the minimum flow rate for supply piping. Isolation valves are critical for maintaining water supply by closing off damaged sections of piping systems.
  • New requirements prohibiting portable cooking equipment in berthing areas, and new requirements for portable electric heaters

The 2016 NFPA 303 is essential for anyone involved with, or responsible for safety in marinas and boatyards, including construction professionals, fire safety personnel, facility owners and maintainers, and insurance professionals.

Product Details

Published:
06/15/2015
ISBN(s):
9781455911738
ANSI:
ANSI Approved
Number of Pages:
33

Click here to purchase
Apply and enforce the latest NFPA 303: Fire Protection Standard for Marinas and Boatyards to provide a minimum acceptable level of safety to life and property from fire and electrical hazards at marinas and related facilities, including boatyards, yacht clubs, boat condominiums, and docking facilities.

Product Details

Published:
08/25/2010
ISBN(s):
9781616650728
ANSI:
ANSI Approved
Number of Pages:
24