Click here to purchase

Product Details

Published:
03/20/2022
ISBN(s):
9781455929290
ANSI:
ANSI Approved
Number of Pages:
34
Note:
This product is unavailable in Ukraine, Russia, Belarus

Click here to purchase
The latest edition of NFPA 557, Standard for Determination of Fire Loads for Use in Structural Fire Protection Design covers everything you need to determine the fire load and fire load density when designing and evaluating the structural fire performance of a building. The 2020 edition includes updated language for defining limited-combustible materials, guidance on fire losses in warehouses, reorganized heat of combustion values, and updated reference documents.

Product Details

Published:
2020
ISBN(s):
9781455923434
Number of Pages:
35

Click here to purchase
First Edition! Use the 2012 NFPA 557 to assist in the determination of fire loads for use in calculations of the performance of structures in a fire.

The 2012 NFPA 557: Standard for Determination of Fire Loads for Use in Structural Fire Protection Design is a brand new document that provides a methodology for the determination of the fire load and fire load density to be used as the basis for the evaluation and design of the structural fire performance of a building.

Developed in response to a request on performance-based design initiatives in the area of fire loads, this Standard covers:

  • Design fundamentals
  • Development of fire loads
  • Occupancy-based fire load density
  • Survey method-based fire load density
  • Documentation, inspection, and maintenance

Five annexes provide additional clarification of requirements. A valuable tool for architects, designers, engineers, and researchers.

Product Details

Published:
01/02/2012
ISBN(s):
9781455903009
Number of Pages:
28

Click here to purchase
Apply the 2016 NFPA 557 to determine fire load and fire load density for use in calculations of the performance of structures in a fire.

Used primarily by designers and engineers, the 2016 NFPA 557: Standard for Determination of Fire Loads for Use in Structural Fire Protection Design provides a methodology for the determination of the fire load and fire load density to be used as the basis for the evaluation and design of the structural fire performance of a building.

Developed in response to a request on performance-based design initiatives in the area of fire loads, NFPA 557 covers:

  • Design fundamentals
  • Development of fire loads
  • Occupancy-based fire load density
  • Survey method-based fire load density
  • Documentation, inspection, and maintenance

Five Annexes provide additional clarification of requirements. Chapter 4 adds criteria for a material to be considered noncombustible, which is consistent with language in NFPA 101®: Life Safety Code® and NFPA 5000®: Building Construction and Safety Code®. The 2016 edition also includes the latest definitions and up-to-date references essential for designers, engineers, and facility managers.

Product Details

Published:
06/15/2015
ISBN(s):
9781455911806
Number of Pages:
36