Safeguard openings in rated walls, floors, and ceilings against the spread of fire and smoke using the latest requirements in NFPA 80, Standard for Fire Doors and Other Opening Protectives.

In a fire event, compliance with NFPA 80, Standard for Fire Doors and Other Opening Protectives, can make all the difference when it comes to occupant life safety and property protection. That is why this standard is referenced in NFPA 101®, Life Safety Code®, building codes, and fire codes nationwide and around the globe.

Proper installation of openings in fire-rated assemblies is critical – and fire doors, fire windows, dampers, and other opening protectives must be inspected and tested periodically to ensure they remain in proper working condition and can help confine a fire should one occur.

If you are responsible for building fire safety, there is no substitute for the latest edition of NFPA 80, Standard for Fire Doors and Other Opening Protectives.

The provisions in this standard can help you ensure the proper installation, inspection, testing, and maintenance of fire door assemblies, fire window assemblies, fire dampers, fabric fire safety curtains, and fire protective curtain assemblies. When changes in the industry occur, everyone needs to know – from manufacturers to designers, engineers, contractors, authorities having jurisdiction (AHJs), fire door inspectors, and building owners.

The 2022 edition of this standard includes several changes, including the following:

  • New provisions in Chapter 1 to clarify that NFPA 80, Standard for Fire Doors and Other Opening Protectives, does not apply for labeled fire door assemblies in openings that are not required to be protected
  • New definitions for annual frequency, corridor damper, and trained rolling steel fire door systems technician
  • New listing requirements for fusible links and revised provisions for fire door signage
  • Relocation of job site preparation criteria from Chapter 4 to Chapter 5
  • New provisions for the inspection and testing of swinging fire doors with fire door hardware
  • Revision of Chapters 6 through 11 and Chapters 14 through 16 to provide consistent references to Chapters 4 and 5 for installation, inspection, testing, and maintenance

Further changes in the 2022 edition of NFPA 80, Standard for Fire Doors and Other Opening Protectives, include a complete rewrite and reorganization of Chapter 7 and a number of changes to Chapter 19.

The changes for dampers in Chapter 19 include the following:

  • New requirements for corridor dampers
  • New listing requirements
  • Definitions relocated to Chapter 3
  • Revised acceptance testing provisions
  • Provisions pertaining to the installation of remote position indication functionality on existing dampers

From fire doors and fire windows to fabric fire safety curtains and dampers, the 2022 edition of NFPA 80, Standard for Fire Doors and Other Opening Protectives, covers it all.

Doors and other fire-rated opening protectives that are not installed, tested, and maintained in accordance with this standard are at risk of compromising the fire-rated construction in which they are installed. Order your copy of the 2022 edition of NFPA 80, Standard for Fire Doors and Other Opening Protectives, today to help protect buildings and occupants. (Print, 105 pp., 2022)

Product Details

Published:
09/15/2021
Number of Pages:
105

Click here to purchase
Safeguard openings in rated walls, floors, and ceilings against the spread of fire and smoke using the latest requirements in NFPA 80, Standard for Fire Doors and Other Opening Protectives.

In a fire event, NFPA 80 compliance can make all the difference in occupant life safety and property protection. That’s why NFPA 80 is referenced by NFPA 101®, Life Safety Code®, model building codes, and fire codes nationwide and around the globe. Proper installation of openings in fire rated assemblies is critical — and fire doors and fire windows are required to be inspected and tested annually to ensure they remain in proper working condition and can help confine a fire should one occur.

If you’re responsible for building fire safety, there’s no substitute for the latest edition of the standard.

NFPA 80’s provisions help you ensure proper installation, inspection, testing, and maintenance of fire door assemblies, fire window assemblies, fire dampers, fabric fire safety curtains, and fire protective curtain assemblies. When changes occur, everyone needs to know — from manufacturers to designers, engineers, contractors, AHJs, fire door inspectors, and building owners. In the 2019 edition:

  • New definitions for inspection mark and field label help users apply inspection, testing, and maintenance provisions.
  • Updated provisions in Chapter 4 recognize job site preparation of fire doors for fire pins.
  • New provisions in Chapter 4 cover measuring clearance under the bottom of fire doors, and a new requirement addresses bottom clearance with the presence of latching hardware devices.
  • The scope of Chapter 5 is expanded to address fire protective curtain assemblies, and a new section in Chapter 5 addresses inspection marks.
  • While the standard now requires damper manufacturers? installation and maintenance instructions be maintained on site for new damper installations, updated Chapter 19 also has the latest requirements for the inspection, testing, and maintenance of fire and combination fire/smoke dampers and adds a remote inspection method.
  • New language clarifies application of inspection requirements for single inaccessible dampers.
  • Annex A contains new and revised figures for typical steel door frame installations.
  • All referenced publications and extracted sections are up-to-date.

From fire doors and fire windows to fabric fire safety curtains and fire dampers, NFPA 80 covers it all.

Doors and other fire-rated opening protectives that are not installed and maintained in accordance with NFPA 80 are at risk for compromising the fire barrier. Protect buildings and occupants by staying up-to-code. (Softbound, Approx. 93 pp., 2019)

Product Details

Published:
05/24/2018
Number of Pages:
104

Click here to purchase
Safeguard buildings, people, and property by following the up-to-date requirements in the 2010 NFPA 80: Fire Doors and Other Opening Protectives.

Revised to reflect the latest advances in equipment and field experience, the 2010 NFPA 80: Fire Doors and Other Opening Protectives maximizes protection against the spread of fire and smoke by providing the latest rules for the full range of opening protectives. From fire doors and fire windows to fabric fire safety curtains and fire dampers, this comprehensive document covers it all!

Order the 2010 edition to keep pace with technical changes that affect:

  • Installation of glazing material in vision panels for new wood doors
  • Installation of glazing and light kits
  • Repair of doors and windows
  • Operation of chute doors
  • Replacement provisions

NFPA 80 is essential for AHJs, building owners, inspectors, and door manufacturers.

Product Details

Published:
06/18/2012
ISBN(s):
9781455904181

Click here to purchase
Protect openings in rated walls, floors, and ceilings against the spread of fire and smoke with NFPA 80.

Expanded, revised, and updated, the 2016 edition of NFPA 80: Standard for Fire Doors and Other Opening Protectives helps you ensure proper installation, inspection, testing, and maintenance of fire door assemblies, fire window assemblies, fire dampers, fabric fire safety curtains, and fire protective curtain assemblies.

Referenced by NFPA 101®: Life Safety Code®, model building codes, and fire codes, NFPA 80 is vital to the fire protection of openings.

Proper installation of openings in fire rated assemblies is critical to both occupant life safety and property protection — and fire doors and fire windows are required to be inspected and tested annually to ensure they remain in proper working condition and can help confine a fire should it occur.

New in the 2016 edition:

  • Expanded requirements for fire door labels help Authorities Having Jurisdiction (AHJs) and end users verify that the assembly or product is appropriate.
  • New section for the required marking of fire rated glazing offers better usability by promoting standardized requirements.
  • New chapter on fire protective curtain assemblies addresses new technology.
  • Additional guidance for use of oversized fire doors reflects industry needs.
  • Reorganized requirements for actuation devices for use with fire doors, fire shutters, and fire windows.
  • A new allowance to use specific products on doors exceeding maximum clearance under the bottom of the door explicitly allows a new category of products, where listed for this use.

From fire doors and fire windows to fabric fire safety curtains and fire dampers, NFPA 80 covers it all.

Doors and other opening protectives that are not installed and maintained in accordance with NFPA 80 are at risk for compromising the fire barrier. That’s why staying up-to-code is essential for everyone involved in building fire safety — from manufacturers to designers, engineers, contractors, AHJs, fire door inspectors, and building owners.

Product Details

Published:
06/15/2015
ISBN(s):
9781455911660
Number of Pages:
101