Click here to purchase

SF-98-3-1
Greenhouse Window U-Factors Under Field Conditions

ABSTRACT:

Field measurements of U-factors are reported for two projecting greenhouse windows, each paired with a picture window of comparable insulation level during testing. A well-known calorimetric field test facility was used to make the measurements. The time-varying U-factors obtained are related to measurements of exterior conditions. For one of the greenhouse windows, which was the subject of a published laboratory hotbox test and simulation study, the results are compared with published test and simulation data and found to be in disagreement. Data on interior and exterior film coefficients are presented, and it is shown that the greenhouse window has a significantly lower interior film coefficient than a conventional window under the same interior conditions. This is advanced as a possible explanation of the disagreement.

AUTHOR: Joseph H. Klems
CITATION: ASHRAE Trans. 1998, Vol.104, Part 1
KEYWORDS: Winter, San Francisco, year1998
YEAR: 1998

Citation: Symposium, ASHRAE Transactions, 1998, Vol 104, pt. 1A, San Francisco

Product Details

Published:
1998
Number of Pages:
11
File Size:
1 file , 220 KB
Product Code(s):
D-7843